BREAKTHROUGH TECHNOLOGY !
For Bonchem's Cooling Water Treatment


BONCHEM THERMOFLOW
® The Ultimate Chemical Package for Deposit Control

THERMOFLOW® product range was developed for deposit control in deep oil exploration wells, where extreme temperatures and severe water qualities lead to excessive deposit formation with the use of traditional scale inhibitors/dispersants. (For further details click here, "Photo Images of Case Studies/Histories")

How does THERMOFLOW© work?
Powerful sequestering agent
Loads the particles with a strong anionic charge
Modifies/distorts the crystal structure

What are the benefits of using THERMOFLOW®?
On equal cost basis - improved results
Superior scale inhibition
Potential result in water savings -
Operate system at increased cycles of concentration
Potential reduction of effluent loading -
Increased cycles = reduced bleed-off
Can deal more effectively with poor quality make-up water
Utilizes crystal modification, sequestration and dispersion
Improved recovery characteristics
Reduces scale formation under laminar flow conditions


 


100 = 100% Dispersion / Inhibition
I = Inhibition
D = Dispersion

The pentogram shows scale inhibition and dispersing capabilities of THERMOFLOW® measured by five parameters generally important for deposit control in water systems.

Relative Performance Profiles
RM 2000 (ACRYLATE MALEATE) =
RM 2010 (PHOSPHONATE) =
RM 2380 (PHOSPHONO MALEATE) =
RM 2900 (POLYACRYLATE) =
RM 3735 (THERMOFLOW) =


DEPOSIT INHIBITION AT 85°C - PROCESS COOLING
% INHIBITION
BLANK
RM 2010
RM 2900
THERMOFLOW®
100        
90        
80        
70        
60        
50        
40        
30        
20        
10        
0        


Test Conditions:
Total Dissolved Solids 5600ppm
Total Hardness 620ppm
Calcium Hardness 480ppm
Sulphates 3120ppm
Silicates 240ppm
pH 8,5
Total Suspended Solids 4000ppm
M-Alkalinity 610ppm
P-Alkalinity 410ppm
(Results are based on equal cost/basis)

DEPOSIT INHIBITION AT 90°C - ASH HANDLING PLANT
% INHIBITION
BLANK
RM 2010
RM 2900
THERMOFLOW®
100        
90        
80        
70        
60        
50        
40        
30        
20        
10        
0        


Test Conditions:
Total Dissolved Solids 3000ppm
Total Hardness 512ppm
P-Alkalinity 1740ppm
Sulphates 2130ppm
M-Alkalinity 1890ppm
pH 10.9
Ammonia 94ppm
Calcium Hardness 145ppm
(Results are based on equal cost/basis)

Refer to the comparative 4 electron photographs, clearly illustrating the high efficacy of THERMOFLOW® in inhibiting and dispersing scale crystals.

NO ADDITIVE
MAG.7500X

RM2010 (10ppm)
MAG.7500X

RM2900 (10ppm)
MAG.7500X

RM 3735 (10ppm)
MAG.7500X


RM 2010 = PHOSPHONATE
RM 2900 = POLYACRYLATE
RM 3735 = THERMOFLOW®